A plant enclosure has to do more than hide equipment
Bespoke plant enclosures, designed around the plant
A plant enclosure must let the plant operate, withstand the site conditions and sit convincingly within the architecture.
Solinear designs, manufactures and installs plant enclosures for rooftops, podiums and ground-level applications. Each enclosure is developed around the equipment, the building and the project-specific performance requirements. The result can combine ventilation, weather protection, acoustic attenuation, access, security and architectural screening in one coordinated package.
Some schemes call for a straightforward louvred screen. Others need structural steelwork, solid or acoustic cladding, bespoke profiles, integrated doors, roof grilles, guarding or a façade treatment that continues the language of the wider building. Solinear is set up for both.
One coordinated plant enclosure package
The most successful plant enclosures are resolved from the inside out: plant first, performance second, architectural treatment throughout.
Solinear can combine proprietary louvre and acoustic products with project-specific steelwork, secondary framing, cladding and access components. This allows tested components to be used where they add value, while the overall assembly is shaped around the building.
Systems and components
- Architectural and weather louvres, including MALLASOL mesh and AQUARIUS XLINE systems where appropriate.
- SOUNDEX acoustic louvres and solid acoustic cladding panels.
- Solid, perforated and profiled metal cladding, including bespoke extrusions and pressed aluminium features.
- Primary or secondary support steelwork, rails and project-specific substructures.
- Single and double access doors, removable panels and coordinated replacement openings.
- Roof grilles, insect mesh, copings, flashings, skirtings and interface details.
What is a plant enclosure?
A plant enclosure is a purpose-built structure that screens mechanical equipment such as air handling units, chillers, cooling towers, generator sets and heat pumps. It may be required by a planning condition or architectural brief where rooftop or ground-level plant would otherwise remain visible. It allows the equipment to operate and be maintained while controlling its visual effect on the building and surrounding area.
Solinear develops each enclosure around the plant and project rather than treating it as an off-the-shelf screen. The design considers manufacturer clearances, airflow, acoustic and weather-protection requirements, supporting structure, access and replacement routes, service interfaces and the architectural treatment.
Applications
Plant enclosures are used across a range of building types and plant applications:
How Solinear develops the design
1. Establish the brief. Review the plant schedule, airflow strategy, acoustic criteria, exposure, access, fire strategy, appearance and programme. Our guide to designing plant screening covers these in more detail.
2. Resolve the interfaces. Coordinate structure, kerbs, waterproofing, adjacent façades, tolerances and items provided by others.
3. Engineer the enclosure. Develop the louvre, panel, framing, door and roof arrangements as one assembly, including structural and installation requirements.
4. Design for manufacture and installation. Set module sizes, joint positions, lifting strategy and assembly sequence around the real constraints of the site.
5. Deliver the finished system. Manufacture and, where required, install the enclosure with the coordinated access components, trims and architectural treatment.
What the enclosure needs to achieve
Information required at enquiry stage
Early information allows the enclosure to be sized and coordinated before the architectural treatment becomes fixed.
- Plant schedule, arrangement, heat rejection and manufacturer clearances.
- Required air paths, maximum pressure drop and any risk of discharge-air recirculation.
- Acoustic criteria supplied by the project acoustic consultant, including frequency-based requirements where available.
- Location, exposure, height, wind criteria and supporting structure.
- Weather-protection requirements and sensitivity of the enclosed equipment.
- Maintenance access, door positions, lifting routes and future replacement strategy.
- Fire strategy, material requirements and relevant interfaces.
- Architectural elevations, finish, joint strategy and coordination with adjacent packages.
Discuss a plant enclosure
If the plant layout, acoustic requirement or architectural treatment is still developing, involve Solinear early. The team can help identify the governing constraints, define the interfaces and develop an enclosure that is practical to manufacture, install and maintain. Send us your plant schedule and elevations and we’ll help you specify it.
Frequently asked questions
Do plant enclosures need planning permission?
Planning permission may be required for a rooftop or ground-level plant enclosure, particularly where it changes the building’s height, external appearance or relationship with neighbouring properties. Requirements vary according to location, building status, existing planning conditions and the applicable planning regime. The position should be confirmed with the project planning consultant or relevant local planning authority before the enclosure design is fixed.
Can an enclosure be installed around existing plant?
Yes. An enclosure can be developed around existing plant, including irregular layouts, established maintenance zones and existing services. Depending on the available supporting structure and fixing locations, it can often be designed as an independently supported assembly so that no load is transferred into the plant itself. This remains subject to site survey, structural review and confirmation of suitable interfaces.
How do plant enclosures manage airflow?
The airflow requirements should be supplied by the M&E engineer, including the design air volume, direction of flow and maximum acceptable pressure drop. Louvre type and face area are then selected using tested aerodynamic and weather-performance data. Free area is one input, but blade geometry, mesh, acoustic treatment, pressure loss and the risk of discharge-air recirculation must also be considered as part of the complete enclosure.




